Last revision April 7, 1994 TJD 8848-8851 = August 14-17, 1992 The MQT for LA detector 3 turned off again after TJD/sec = 8848/55556 (time of last packet before gap based on CONT data) and definitely off before TJD/sec = 8848/58200 (time of first packet after gap based on CONT data). Detector module 3 was turned off by command after TJD/sec = 8851/54007 (time of last good packet based on DISCLA data) and turned on by command before TJD/sec = 8851/54054 (time of first good packet based on DISCLA data). Therefore, the MQT for LA detector 3 (affects CONT and HER data) was out between 8848/55556 and 8851/54054 and the entire module 3 (also affects DISCLA, DISCSP, and SHER data) was out between 8851/54007 and 8851/54054. The gain for LA detector 3 was out of balance between 8848/58000 and 8851/54054 (no ramp back to normal).