Last revision February 12, 1996 TJD 10122 = February 9, 1996 The MQT for LA detector 3 turned off again. This was first discovered by the FOT who noticed AGCOUT messages. The time that it went off was after TJD/sec = 10122/25036.4896 (time of last good packet based on CONT data). Detector module 3 was turned off by command after TJD/sec = 10122/79615.6896 (time of last good packet based on DISCLA data) and turned on by command before TJD/sec = 10122/79718.0896 (time of first good packet based on DISCLA data). Therefore, the MQT for LA detector 3 (affects CONT and HER data) was out between 10122/25037 and 10122/79717 and the entire module 3 (also affects DISCLA, DISCSP, and SHER data) was out between 10122/79616 and 10122/79717. Flags 73 and 56 (also temporarily flag 50 for CDFITS) were set for the range 10122/79616 to 10122/79717. The gain for LA detector 3 was out of balance (no flag 64 was set) between 10122/25036.4896 and 10122/86400 (back in balance at nearly exactly the end of the day).